Описание

  • Analog output (0...10 V DC)
  • Linear output signal proportional to distance
  • Usable with or without glass fiber-optic cable
This sensor is suitable for analog distance measurements and can be used with or without a glass fiber cable. The output voltage is dependent upon the brightness of the object to be measured, as bright objects reflect transmitted light better than dark objects.
Working Range 100...1000 mm
Measuring Range 900 mm
Resolution 20 mm
Linearity 5 %
Light Source Infrared Light
Wavelength 880 nm
Service Life (T = +25 °C) 100000 h
Max. Ambient Light 10000 Lux
Opening Angle 12 °
Electrical Data
Supply Voltage 20...30 V DC
Current Consumption (Ub = 24 V) < 40 mA
Switching Frequency 30 Hz
Response Time 15 ms
Temperature Drift 1 mm/K
Temperature Range -10...60 °C
Analog Output 0...10 V DC
Output Resistance Analog Output 1 kOhm
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III
Mechanical Data
Setting Method Potentiometer
Housing Material CuZn, nickel-plated
Full Encapsulation yes
Degree of Protection IP65
Connection M12 ? 1, 4-pin
Output
Analog Output yes
''